Introduction
Overview
This guide demonstrates how to replace a fan in an Open Compute V2 server system.
-
-
Power off both server systems in the Open Compute V2 chassis.
-
Remote Power Down: Login to each server to power it off.
-
shutdown -h now;exit -
Hardware Power Down: Press and hold the power switch for at least three seconds, as annotated.
-
-
-
Disconnect all of the peripheral cables from the server sleds.
-
Engage the locking mechanism on the right side of the Open Compute V2 chassis.
-
Pull the chassis away from the rack.
-
Place the chassis on a work surface.
-
-
-
Identify the Open Compute V2 fan that needs to be replaced.
-
From left to right, fans are oriented in the Open Compute V2 chassis as follows:
-
Node 0, Sys Fan 0
-
Node 0, Sys Fan 1
-
Node 1, Sys Fan 0
-
Node 1, Sys Fan 1
-
-
-
Disconnect the fan power cable.
-
-
-
Remove fan from the server chassis.
-
-
-
Place new fan in the chassis.
-
Ensure the rubber grommets sit correctly in chassis, as shown.
-
-
-
Slide the chassis into the rack.
-
-
-
Power on the server by pressing the power button.
-