Perform a warm shut down on the server. Run:
-
ssh -l root <hostname> shutdown -h now
-
-
-
Disconnect the 10G cable NIC.
-
-
-
Pull the green retention plunger upwards and twist 90 degrees to lock in the upright position.
-
Using the handle located at the left side of the server sled, pull the sled outwards.
-
-
-
Remove the server sled and place it onto a crash cart or work bench for service.
-
-
-
Disconnect the following cables by pressing down on the metal retention tabs pulling away from the HDD:
-
SATA cable
-
Power cable
-
-
-
Pull the two PCI Riser Cage locking handles towards the front of the server, as shown.
-
-
-
Lift the PCI Riser Cage from the server chassis.
-
-
-
Locate the (3) retention tabs which secure the NIC to the (4) motherboard standoffs.
-
-
-
To release the NIC, carefully press down on the retention tabs as shown.
-
Lift the NIC to remove it from the motherboard.
-
-
-
Align the NIC onto (4) the nylon standoffs.
-
-
-
Press down firmly to seat the NIC.
-
Ensure all (4) corners are secure.
-
-
-
Align (4) PCI Riser Cage slots with the chassis keys.
-
Lower the PCI Riser Cage onto the server chassis and press firmly to seat.
-
-
-
Lock the PCI Riser Cage by pushing the two handles towards the rear of the server until they click into place.
-
-
-
Connect the SATA and Power cables as shown.
-
-
-
Insert the server sled into the rack as shown.
-
If the green retention plunger is still in the upright position, twist it 90 degrees to release it. This will secure the server.
-
-
-
Press the power button to power-on the server.
-