    • Perform a warm shut down on the server. Run:

    • ssh -l root <hostname> shutdown -h now

  1. Disconnect the 10G network interface cable. Pull the 10G network interface cable pull-tab. Pull the 10G network interface cable pull-tab.
    • Disconnect the 10G network interface cable.

    • Pull the 10G network interface cable pull-tab.

  2. Pull the green retention plunger upwards. Pull the server away from the rack, as shown. Pull the server until about (2) inches of the black lid is exposed.
    • Pull the green retention plunger upwards.

    • Pull the server away from the rack, as shown.

    • Pull the server until about (2) inches of the black lid is exposed.

  3. The PCI riser card and assembly are defined as one Field Replaceable Unit (FRU) in the ORV1 Leopard assembly. Disconnect the power and SATA connectors from the Hard Disk Drive (HDD).
    • The PCI riser card and assembly are defined as one Field Replaceable Unit (FRU) in the ORV1 Leopard assembly.

    • Disconnect the power and SATA connectors from the Hard Disk Drive (HDD).

  4. Loosen the (2) thumbscrews, shown. Loosen the (2) thumbscrews, shown.
    • Loosen the (2) thumbscrews, shown.

  5. Engage the PCI riser card assembly, as shown. Push the PCI riser card assembly upwards. The PCI riser card will be properly unseated when a distinctive 'click' is felt.
    • Engage the PCI riser card assembly, as shown.

    • Push the PCI riser card assembly upwards.

    • The PCI riser card will be properly unseated when a distinctive 'click' is felt.

    • Remove the PCi riser card assembly from the server.

    • Place the assembly on the crash cart.

  6. Locate the Trusted Platform Module (TPM). To remove, grip the module on each side, then pull upwards as shown. To remove, grip the module on each side, then pull upwards as shown.
    • Locate the Trusted Platform Module (TPM).

    • To remove, grip the module on each side, then pull upwards as shown.

  7. Scan the barcode located on the top of the TPM Module.
    • Scan the barcode located on the top of the TPM Module.

  8. The TPM module and socket are keyed. Ensure that both are aligned prior to installation. The TPM module and socket are keyed. Ensure that both are aligned prior to installation.
    • The TPM module and socket are keyed. Ensure that both are aligned prior to installation.

  9. Once the TPM module connector has been aligned, insert it into the socket until resistance is felt. Once the TPM module connector has been aligned, insert it into the socket until resistance is felt.
    • Once the TPM module connector has been aligned, insert it into the socket until resistance is felt.

  10. Install the PCI riser card. Connect the boot hard disk drive (HDD) SATA and power cables. PCI riser card installation is opposite of the removal process.
    • Install the PCI riser card.

    • Connect the boot hard disk drive (HDD) SATA and power cables.

    • PCI riser card installation is opposite of the removal process.

    • Route the SATA and power cable under the cable management tab, as shown.

  11. Press the power button.
    • Press the power button.